Precise setting of the bending radius of medical catheters: scientific considerations under functional requirements

Date:2024-12-05

Catheter functional diversity and bending performance requirements
There are many types of medical catheters, each type is designed for a specific medical task, and its functional requirements are therefore different. For example, drainage catheters are mainly used to drain body fluids (such as pleural effusions and peritoneal effusions) out of the body. Such catheters are usually required to have good flexibility and a moderate bending radius to adapt to the anatomical structure of different parts while ensuring drainage efficiency. For catheters used for drug injection, it is necessary to ensure that the drugs can be accurately delivered to the target tissue or blood vessels. The requirements for the bending radius may be more stringent. It must be able to pass through the complex vascular network smoothly, and avoid drug accumulation at the bend, which affects the treatment effect.

Catheter selection in cardiac surgery and peripheral vascular surgery
In cardiac surgery, catheters often need to pass through extremely narrow and complex vascular structures inside and around the heart. In this case, it is particularly important for the catheter to have a very small bending radius, which can ensure that the catheter can smoothly enter the target area, such as small blood vessels such as coronary arteries, and perform precise operations such as balloon dilatation and stent implantation. Such catheters are usually made of advanced materials, such as stainless steel alloys or special polymers, to improve their strength and kink resistance while maintaining the necessary softness.

In contrast, the design of catheters in peripheral vascular surgery focuses on reducing damage to the vessel wall and promoting postoperative recovery. Therefore, such catheters often have a larger bending radius to reduce friction during operation and reduce the risk of vascular damage. Especially when dealing with diseases such as arteriosclerosis and varicose veins, an appropriate bending radius can effectively improve the safety and success rate of surgery.

Comprehensive considerations for setting the bending radius
When determining the bending radius of medical catheter curving, in addition to direct functional requirements, it is also necessary to comprehensively consider the physical properties of the material, individual differences in patients, specific anatomical characteristics of the surgical site, and surgical technology requirements. For example, the elastic modulus, yield strength and other properties of the material will directly affect the bending performance of the catheter; physiological differences in patients such as vascular diameter and vascular wall thickness are also factors that cannot be ignored when formulating catheter specifications. In addition, with the advancement of medical imaging technology, such as the application of technologies such as three-dimensional reconstruction and virtual surgical planning, more accurate data support is provided for the personalized design of the catheter bending radius.